Phase 1 of 4 · in flight

The Safe-Pump Plan

Turn a mains-powered hazard into a low-voltage, hands-off fountain.

1

part this phase

1 / 1

already owned

0

to buy

2

jobs for the kids

The Step2 table is a great toy with one bad habit: the obvious way to make its rain shower run is to drop a submersible pump in the basin and plug it into the wall — mains AC, in the water, next to a one- and a three-year-old. The whole point of this kit is to never do that. The design is settled before a single hole gets drilled: mains stays sealed inside an AC/DC brick, only low-voltage 24V DC ever reaches the water side, and the pump itself sits dry in a vented crate, not in the basin.

After this phase: A design where the worst-case electrical fault can only put 24 volts onto a cable — the same safety approach as the low-voltage LED lighting people bury around their pools.

The thinking

Mains never touches the water

The architecture is mains → AC/DC brick → 24V DC → pump. The brick does the dangerous part (240→24V) sealed up and out of the splash zone; everything on the water side runs on low-voltage DC. Even a total failure of the brick can only deliver 24 volts to the pump cable — below the threshold to shock through wet skin. It's the same reason landscape lighting around pools is low-voltage.

The pump stays dry

Submersible pumps are convenient and exactly the wrong call here — you can't see them, can't service them without reaching into the water, and they put a powered device in the basin. This pump lives in a crate beside the table and pulls water through a hose. Dry, visible, serviceable.

A mag-drive, sine-wave pump

The Jebao DCW-2500 is mag-drive — the motor turns the impeller through a magnetic coupling, so there's no shaft penetrating the wet chamber and nothing live can ever reach the water, even mechanically. Its controller is a true sine wave (smoother, quieter, and longer-lived than the PWM clones), and it's variable from 30–100%, so it's a gentle bubbling fountain, not a firehose pointed at a toddler.

GFCI upstream, belt and suspenders

The brick plugs into a covered outdoor GFCI outlet, which cuts power within ~25ms on any leakage — fault protection ahead of the brick on top of the low-voltage isolation behind it.

Bill of materials1 part
  • Jebao DCW-2500 pump + sine-wave controllerhaveJebao · 660 GPH, 30–100% in 10 steps. Mag-drive, separate IEC AC brick.~$55

For the kids

This phase is all engineering — their part is simply that the result is safe to stand at:

  • Nothing dangerous to touch — the only thing near the water runs on 24 volts.
  • A fountain they can put their hands in without anyone hovering.